Pressure Scout-LR
LoRaWAN® Intrinsically Safe Wireless Pressure Sensor
Features
- Powers integrated pressure sensor and radio for years with an internal battery
- Class 1 Division 1 Intrinsically safe system (pending)
- Rugged design for outdoor environments
- LoRaWAN® Radio for up to 10 mile range (SignalFire 900MHz proprietary radio available)
- ½” NPT Process connection standard
- Rapid pressure sampling with configurable alarms and report by exception
- Extremely low power and long battery life
- Reports Maximum, Minimum and Average pressures when configured for rapid pressure sampling
- Class A LoRaWAN® device. May be configured remotely via downlink messages
- Local or remote zeroing
The PressureScout-LR uses LoRaWAN network to wirelessly send pressure measurements with a range of up to 10 miles (16km). The compact and industrial grade design is ideal to monitor pressure in harsh environments. The PressureScout-LR offers unique sampling methodology to report by exception while offering a great battery life of up to 10 years. It also allows remote applications to make changes remotely and to get device alarms.
Operating Temp: -40 to +176°F (-40°C to 80°C)
Humidity: 0% – 100% condensing
Power: “D” Cell Lithium battery pack. Field replaceable. Class 1 Division 1 certified.
Battery Life: 2–10+ years depending on sample and reporting frequency. Battery Life Examples: 5-second pressure sample interval with a 1-minute reporting interval = 2 years. 5-minute sample and reporting interval = 10 years
Data Format
UpLink Data: Current Pressure, Max, Min and Average pressure sent at the configure report interval
Device information: including battery voltage, firmware revision, sensor span, sample and report interval and alarm settings are sent at join and once every 12-hours
DownLink Data: The sample and report interval and alarm settings may be configured remotely
Transmit Data by Exception: Configurable minimum and maximum alarm pressure thresholds, pressure sample rate 1 seconds minimum.
Intrinsically Safe: Class 1 Division 1, Temp Code T3, Groups C&D. (certification pending)
Internal Diagnostics: Battery voltage, signal strength, error conditions
LoRaWAN Radio:
LoRaWAN compliant radio: supports Adaptive Data Rate (ADR)
Data Update Rates: User-selectable. 1 minute to 12 hours.
Range: Up to 10 miles (line of sight)
Radio Power: 19 dBm
Receive Sensitivity: -130 dBm
Radio Frequency: 902–928 MHz, LoRaWAN 1.0.4 compliant, OTAA provisioning, license-free ISM Band Compliant with FCC Part 15 and Industry Canada.
PERFORMANCE AT 77°F/25°C
Accuracy: <±0.25% BFSL; ≤ ± 0.5% BFSL (>10,000 PSI)
Stability (1 year): ±0.25% FS, typical
Over Range Protection: 2X Rated Pressure, Minimum
Burst Pressure: 5X or 40,000 PSI (whichever is less)
Pressure Cycles: >100 Million
Process Connection: 1/2” NPTM 316L Stainless Steel Standard, F250C Autoclave for pressure >10,000 psi, Other process connections/material available
Standard Pressure Ranges: 0-100 psi, 0-500 psi, 0-1000 psi, 0-3000 psi, 0-5000 psi, 0-10,000 psi, 0-15,000 psi*, 20,000 psi*
Low Pressure Ranges: 0-2 psi, 0-20 psi
*additional lead-time may apply
THERMAL LIMITS
Operating Range: -40 to +176°F (-40 to +80°C)
Compensated Range: 5°F to 150°F (-15°C to +65°C)
TC Zero: <±1% of FS
TC Span: <±1% of FS